A total of comprising:
listed below;
from the general elective units listed below.
Choose a total of 180 elective units from the list below, of which between 0 and 90 can be taken from Group A; and between 0 and 90 must be taken from Group B; and between 90 and 180 must be taken from Group C; or all electives units of 180 can be taken from Group C.
, may be selected, with appropriate contextualisation, from any relevant nationally endorsed Training Package or accredited course, provided selected units contribute to the vocational outcome of the qualification. Previously assigned weighting points are listed in the UEE Electrotechnology Training Package Companion Volume Implementation Guide (CVIG), if not listed weighting points will be 10 points, unless directed from the Electrotechnology Industry Reference Committee (IRC).
There are units of competency within this qualification that contain pre-requisites. Units of competency that have a pre-requisite requirement are identified by this symbol *. Refer directly to the units of competency to identify pre-requisite requirements to ensure all are complied with. A list of all pre-requisites is also provided in the UEE Pre-requisite Companion Volume.
Where imported units are selected, care must be taken to ensure all pre-requisite units specified are complied with.
|
|
|
UEECD0007
|
Apply work health and safety regulations, codes and practices in the workplace
|
20
|
UEECD0010
|
Compile and produce an energy sector detailed report
|
60
|
UEECD0016
|
Document and apply measures to control WHS risks associated with electrotechnology work*
|
20
|
UEECD0019
|
Fabricate, assemble and dismantle utilities industry components*
|
40
|
UEECD0020
|
Fix and secure electrotechnology equipment*
|
20
|
UEECD0024
|
Implement and monitor energy sector WHS policies and procedures
|
20
|
UEECD0027
|
Participate in development and follow a personal competency development plan
|
20
|
UEECD0042
|
Solve problems in ELV single path circuits*
|
40
|
UEECD0051
|
Use drawings, diagrams, schedules, standards, codes and specifications*
|
40
|
UEERA0031
|
Diagnose and rectify faults in air conditioning and refrigeration control systems*
|
60
|
UEERA0032
|
Diagnose and rectify faults in complex air conditioning/refrigeration systems*
|
100
|
UEERA0035
|
Establish the basic operating conditions of air conditioning systems*
|
20
|
UEERA0036
|
Establish the basic operating conditions of vapour compression systems*
|
60
|
UEERA0044
|
Find and rectify faults in single phase motors and associated controls*
|
40
|
UEERA0045
|
Find and rectify faults in three phase motors and associated controls*
|
30
|
UEERA0050
|
Install refrigerant pipe work, flow controls and accessories*
|
60
|
UEERA0051
|
Install, commission, service and maintain air conditioning systems*
|
80
|
UEERA0052
|
Install, commission, service and maintain low temperature systems*
|
40
|
UEERA0053
|
Install, commission, service and maintain medium temperature systems*
|
60
|
UEERA0059
|
Prepare and connect refrigerant tubing and fittings*
|
40
|
UEERA0062
|
Recover and charge refrigerants*
|
40
|
UEERA0079
|
Safely handle refrigerants and lubricants*
|
40
|
UEERA0081
|
Select refrigerant piping, accessories and associated controls*
|
40
|
UEERA0094
|
Verify functionality and compliance of refrigeration and air conditioning installations*
|
40
|
UEERE0015
|
Implement and monitor energy sector environmental and sustainable policies and procedures
|
20
|
UEERL0001
|
Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply*
|
20
|
UEERL0002
|
Attach cords, cables and plugs to electrical equipment for connection to 1000 V a.c. or 1500 V d.c.*
|
20
|
UEERL0004
|
Disconnect - reconnect electrical equipment connected to low voltage (LV) installation wiring*
|
60
|
UEERL0005
|
Locate and rectify faults in low voltage (LV) electrical equipment using set procedures*
|
20
|
|
|
BSBOPS203
|
Deliver a service to customers
|
20
|
CPCWHS1001
|
Prepare to work safely in the construction industry
|
10
|
HLTAID009
|
Provide cardiopulmonary resuscitation
|
10
|
ICTICT214
|
Operate application software packages
|
20
|
UEECD0011
|
Comply with scheduled and preventative maintenance program processes
|
20
|
UEECD0035
|
Provide basic instruction in the use of electrotechnology apparatus
|
20
|
UEECO0002
|
Maintain documentation
|
20
|
UEECO0015
|
Provide quotations for installation or service jobs
|
20
|
UEECO0017
|
Source and purchase material/parts for installation or service jobs
|
20
|
|
|
UEEIC0002
|
Assemble, enter and verify operating instructions in microprocessor equipped devices*
|
20
|
UEEIC0013
|
Develop, enter and verify discrete control programs for programmable controllers*
|
60
|
UEERA0005
|
Apply safety awareness and legal requirements for ammonia refrigerant
|
10
|
UEERA0006
|
Apply safety awareness and legal requirements for carbon dioxide refrigerant
|
10
|
UEERA0007
|
Apply safety awareness and legal requirements for flammable refrigerants
|
10
|
UEERA0046
|
Install and commission ammonia refrigeration systems, components and associated equipment*
|
20
|
UEERA0047
|
Install and commission carbon dioxide refrigeration systems, components and associated equipment*
|
20
|
UEERA0048
|
Install and commission flammable refrigerant air conditioning and refrigeration systems*
|
20
|
UEERA0054
|
Maintain microbial control of refrigeration and air conditioning systems
|
20
|
UEERA0065
|
Repair and service ammonia refrigeration systems*
|
20
|
UEERA0066
|
Repair and service carbon dioxide refrigeration systems*
|
20
|
UEERA0067
|
Repair and service secondary refrigeration systems*
|
20
|
UEERA0068
|
Repair and service self-contained carbon dioxide refrigeration and heat pump systems*
|
20
|
UEERA0069
|
Resolve problems in beverage dispensers*
|
40
|
UEERA0070
|
Resolve problems in central plant air conditioning systems*
|
40
|
UEERA0072
|
Resolve problems in hydronic systems*
|
40
|
UEERA0073
|
Resolve problems in ice making systems*
|
20
|
UEERA0074
|
Resolve problems in industrial refrigeration systems*
|
20
|
UEERA0075
|
Resolve problems in post-mix refrigeration systems*
|
20
|
UEERA0076
|
Resolve problems in refrigerated beverage vending cabinets*
|
20
|
UEERA0077
|
Resolve problems in transport refrigeration systems*
|
20
|
UEERA0078
|
Resolve problems in ultra-low temperature refrigeration systems*
|
20
|
UEERA0084
|
Service and repair self-contained flammable refrigerants air conditioning and refrigeration systems*
|
20
|
UEERA0097
|
Install, commission, service and maintain variable refrigerant flow air conditioning systems*
|
40
|
UEERA0098
|
Inspect, test and repair fire and smoke control features of mechanical services systems*
|
80
|
|
|
UEECD0013
|
Develop and implement energy sector maintenance programs
|
60
|
UEEIC0014
|
Develop, enter and verify programs in supervisory control and data acquisition systems*
|
60
|
UEEIC0015
|
Develop, enter and verify word and analogue control programs for programmable logic controllers*
|
60
|
UEERA0010
|
Commission complex heating, ventilation and air conditioning (HVAC) systems*
|
80
|
UEERA0011
|
Commission complex refrigeration systems and equipment*
|
80
|
UEERA0012
|
Commission complex refrigeration/air conditioning control systems*
|
40
|
UEERA0013
|
Commission refrigeration/air conditioning hydronic systems*
|
80
|
UEERA0033
|
Diagnose faults in complex HVAC/refrigeration control systems*
|
80
|
UEERA0056
|
Monitor and adjust refrigeration energy management systems*
|
40
|